Home---Specs---Order-- Testimonials---Support

Professional Courtesy - If you order in the month of you can count your current purchase toward quantity pricing on any more units you purchase in the next 30 days.

Prove to yourself how effective this air purifier is - 60 day Money Back Guarantee. You must be completely satisfied or return your product for refund.

The XJ-3000C features:

  • Low & Efficient Energy Consumption
  • No Weekly Maintenance (Like Infomercial Brands)
  • Each unit covers 500 sq ft
  • 3-Year Warranty
  • 60-day Money-Back Guarantee
  • Portable & Compact 10 lbs., 15" (W), 13" (H), 7.75 (D)
  • 3-Stage Air Filter Cartridge and UV Lamp Included
  • Replacing the Filter Cartridge and the UV Bulb Couldn't Be Easier - And It's All The Maintenance You'll Need To Do

    The filter cartridge contains the pre-filter, the HEPA filter and the activated carbon air filter in one easy-to change pack. Units placed in treatment rooms will likely require a filter change every 3 to 6 months, depending on dust volume. The filter cartridge lasts one to two years in waiting rooms and offices. Click here to learn how easy it is to change it. removing cover of the XJ-3000C HEPA air filter

    Filter Cartridge

    Replacing the UV bulb is quick and easy. Click here to learn how it's done.

    UV Bulb

    Changing the Filter

    Filter Change - Step # 1 - Open and check

    Units placed in treatment rooms will likely require a filter cartridge change every 3 to 6 months, depending on dust volume. The filter cartridge lasts one to two years in waiting rooms and offices. We recommend you perform the check described below every three months until you have a pretty good idea of the time a filter cartridge will last in your environment.

    Unplug the unit and open the front cover.

    • If the blue side of the filter (the pre-filter) is dirty, it can be cleaned with hand-held vacuum to remove dirt from its fibers. This will prolong the life of the filter cartridge.
    • If the white (HEPA) side of the filter cartridge is dark gray in color, you should change the filter cartridge. Proceed to the next step. (You can order spare filters by clicking here.)

    replacing the room air filter cartridge

    Filter Change - Step # 2 - Replace the cartridge

    • Remove the old filter and throw it away.
    • Remove the wrapping from the new room air filter cartridge.
    • Remove the cardboard cover on the back side of the cartridge. (It detaches in the same way that you open a box of tissues.)
    • Place the new filter in its proper position.

    Filter Change - Step # 3 - Close the unit

    Put the front cover back on and begin operating again. That's it. No other filter maintenance is required.

    Back to Top

    Changing the UV Bulb

    UV Bulb Change - Step #1 - Preparatory

    You should check that the bulb is operating periodically. You can do this by looking down through the top of the unit, through the fans. If you see a blue-ish glow, the bulb is still working. (You may need to do this in a room where the lights are dimmed.) NOTE: The bulb typically lasts 12-15 months.

    If you determine that the bulb is not working, proceed to step #2.

    (You can order spare bulbs by clicking here.)

    UV Bulb Change - Step #2 - Remove old bulb and replace it with the new one

    • Unplug the unit and open the front cover. Remove the air filter cartridge.
    • The ends of the bulb are held in place by two very simple plastic clamps. Gently snap their covers open. (The one on the left snaps over to the left, the one on the right, to the right. It won't take much force to open them.)
    • Remove the expired UV lamp. Handle the UV bulb on both ends in order to avoid breaking it.
    • Press the new bulb into the UV bulb slot. The metal pins poking out each end of the bulb should be firmly in contact with the metal conductors inside each clamp. Close the plastic clamps over the bulb on each end.
    • Place the filter cartridge back in its compartment (with the blue side facing out) and put the front cover back on. The air purifier is now ready for operation again.
      Bulb with both clips closed.
      Bulb with the left clip open.
      (Make sure both clips are open before extracting the bulb.)

    UV Bulb Change - Step #3 - Insert new bulb

    Press the new bulb into the UV bulb slot. The metal pins poking out each end of the bulb should be firmly in contact with the metal conductors inside each clamp. Close the plastic clamps over the bulb on each end.

    UV Bulb Change - Step #4 - Finishing up

    Place the filter cartridge back in its compartment (with the blue side facing out) and put the front cover back on. The air purifier is now ready for operation again.

    Caution! Make sure that the air filter cartidge is in place before operating the XJ-3000C air purifier or direct UV rays may escape through the front cover of the unit. Direct UV light can cause skin or eye damage.

    Back to Top